Eaton 93E UPS 93E20KMBSBI

  • كفاءة شاملة: 94% (98% في الوضع الاقتصادي)
  • وقت الانتقال للحمل الكامل: 0 ثانية
  • مدة التشغيل بنصف الحمل: 19 دقيقة / بالحمل الكامل: 8 دقائق
  • الوظائف المدمجة: إدارة الشبكة
  • التوازي من أجل السعة والازدواجية
SKU:93E20KMBSBICategories:UPSTags:Battery, Charging, Phase, Power, Protection

المواصفات الفنية

General
  • Application: Data center/facility/IT
  • Color: Black
  • Construction Type: Free-standing model
  • Form Factor: Tower
  • Mounting Method: Tower
  • Topology: Online
  • KVA Rating: 20 kVA
  • Wattage: 18 kW
  • Output Effective Power: 18000 W
  • Output Apparent Power: 20000 VA
  • Power Consumption: 296
Alarms & Shutdown
  • Audible Alarms: Yes
  • Auto Shutdown Function: Yes
Battery
  • Internal Battery Included: Yes
  • User Replaceable Batteries: No
  • Battery Charger Type: ABM technology
  • External Battery Connection: Hardwired
  • Start-on-Battery: No
  • Runtime at Half Load: 19 min
  • Runtime at Full Load: 8 min
Efficiency
  • Efficiency (Eco-Mode): 98%
  • Improved Efficiency Mode: High Efficiency
  • Efficiency (Improved Efficiency Mode): 98%
  • Overall Efficiency: 94%
Connectivity & Communication
  • Number of Communication Slots: 2
  • Type of Interface: Other
  • User Interface (HMI): Graphical LCD
  • SNMP: No
  • Potential Free Switch Contact: No
  • Integrated Functionality: Network Management
  • Communication Interface: USB, RS232
Input
  • Feed Type: AC
  • Input Connection: Fixed connection
  • Input Nominal Voltage: 400V default (380/400/415V)
  • Phase (Input): 3
  • Input Frequency – Min: 50 Hz
  • Input Frequency – Max: 60 Hz
  • Input Voltage – Min: 380 V
  • Input Voltage – Max: 415 V
Output
  • Number of Output Connections Fixed Connection: 1
  • Output Frequency: 50 Hz (50/60 Hz programmable)
  • Output Power Factor: 0.9
  • Phase (Output): 3
  • Transition Time for Full Load: 0 s
  • Voltage Distortion Output (Linear Load) – Max: 2%
  • Output Voltage – Min: 380 V
  • Output Voltage – Max: 415 V
  • Secondary Frequency Min: 50 Hz
  • Secondary Frequency Max: 60 Hz
  • Primary Frequency – Max: 60 Hz
  • Primary Frequency – Min: 50 Hz
Modules & Bypass
  • Hot-Swappable Power Modules: No
  • Internal Maintenance Bypass: Yes
Parallel Capability
  • Parallelable: Parallel for capacity and redundancy
  • Number of Parallel Units: 4
Package Contents
  • UPS
  • User manual
  • Safety instructions

We are here to answer any question you may have.

هذا الموقع مسجل على wpml.org كموقع تطوير. قم بالتبديل إلى مفتاح موقع إنتاجي لـ remove this banner.