Fire Alarm

Sensitivity (UL Applications): 0.5% to 4.0% per foot obscuration Size (Height): 2.0″ (51mm) Operating Temperature Range: 32°F to 122°F (0°C to 50°C) UL/ULC Listed Velocity Range: 0-4000 ft/min. (1219.2 m/min.) Voltage Range: 15 – 32 volts DC peak

Operating Temperature: 32°F – 100°F (0°C – 38°C) Humidity: 10 to 93% non-condensing Operating Voltage: 15 – 32VDC Velocity: 0 – 4000 fpm (0 – 20 m/sec) (suitable for installation in ducts) UL Listed, FM Approved, CSFM Listed, MEA Listed

Height: 2.0″ (51mm) when installed in a B300-6 base Operating Temperature Range: -4°F to 100°F (-20°C to 38°C) Humidity: 10% to 93% non-condensing Voltage Range: 15 to 32VDC Standby Current (@ 24 VDC): 200µA

Addressable device capacity: 2100 (IDP/SK) or 2032 (SD) AC Power: 120 VAC, 60 Hz, 5A or 240VAC, 50/60Hz, 2.8A Battery Charger Capacity: 17-55 AH Dimensions: 16.4” W x 26.4” H x 4.1” D (41.66cm W x 67.06cm H x 10.41cm D) UL Listed: S2766

Dimensions: 5.5″ H x 4″ D (14cm x 10.2cm) Housing Material: LEXAN polycarbonate resin Bi-Colored LED: Blinking Green (Normal), Steady Red (Alarm) Operating Voltage: 15 – 32VDC Operating Temperature: 32º-120ºF (0ºC – 49ºC)

120 VAC Input: 2 A maximum @ 102 to 132 VAC, 50/60 Hz Power Supply Output Rating: 6 A total NAC Ratings: 3 A each for Special Application Appliances Battery capacity range: 6.2 Ah up to 33 Ah Operating Temperature: 32° to 120°F (0° to 49° C)

Communications: IDNet communications, one address NAC output ratings: Special application or regulated 24 VDC appliances = 0.5 A; Audio rating for speakers = 0.5 A at 25 VRMS (12.5 W) or 70.7 VRMS (35 W) IDNet communications, general reference: 10,000 ft (3048 m) maximum total wiring distance Dimensions: 4 in.…

Communications and Sensor Supervisory Power: IDNet or MAPNET II communications, auto-selected UL Listed Operating Temperature Range: 32°F to 100°F, 0°C to 38°C Operating Temperature Range with 4098-9714 Smoke Sensor: 15°F to 122°F, -9°C to 50°C Humidity Range: 10% to 95% RH 4098-9714 Smoke Sensor Air Velocity Rating: 0 to 4000…

18 AWG UTP Data Rate (baud): 9600 18 AWG UTP Distance: 17,000 ft (5.4 km) 24 AWG Telephone Cable UTP Data Rate (baud): 57.6 k Multi-mode Fiber Maximum Distance: 16400 ft (5 km) Single-mode Fiber Maximum Distance: 82000 ft (25 km)

Sound Output: 101 dB Degree of Protection: IP65 Operating Temperature: -10 °C to 55 °C System Typology: Conventional (Non-addressable) EN Certification Standards: EN54 Pt3 (Fire Alarm Sounders)